網站首頁
產品目錄
  消息
聯繫我們
文件下載

產品目錄 

 

GE露點儀MTS6

型號︰GE露点仪MTS6
品牌︰GE
原產地︰美國

 共有 440 相關信息  
上一個432433434435436下一個

產品描述

GE
Measurement & Control Solutions
Moisture Target™
Series 6
Moisture Analyzer
Features
• Low-cost, single-channel hygrometer for OEM
applications
• M Series moisture probe or VeriDri moisture
transmitter compatible
• NEMA 4 weatherproof membrane front display/
keypad
• Built-in isolated current or voltage analog output
• MicroSD card for logging data up to 32 GB
• Panel-mount and board-level confi gurations
• Fail-safe fault alarm relay
• Two Form C measurement alarm relays
• Upgrades from MTS5 with adaptor face plate
Applications
This single-channel analyzer measures moisture
in compressed air and gases. Designed for
permanent installations, it is used in conjunction
with M Series moisture probe or VeriDri moisture
transmitter for air/gas dryer original equipment
manufacturer (OEM) applications:
• Regenerative desiccant air or gas dryers
• Plastic drying applications prior to injection/
blowmolding
• Medical air dryers
• Glove box monitoring
Low Cost, Real-Time
Moisture Measurement
The Moisture Target Series 6 is an economical, single
channel, aluminum oxide hygrometer in the Moisture
Series line of analyzers. It is intended for OEM
applications requiring low-cost, accurate, real-time
moisture measurement.
Improves OEM Product
Performance
The Moisture Target Series 6 can signifi cantly
enhance the performance of OEM products by
allowing closed-loop control of moisture. For
example, in a regenerative dryer application it
can improve effi ciency by initiating desiccant bed
regeneration when needed, rather than on an openloop
timed cycle.
Panel-Mount
The panel-mount Moisture Target Series 6 comes
in a compact DIN standard meter housing for
applications where space is at a premium. The case
slides directly into the panel cutout, and is held in
place from the rear by captive screws.
The Moisture Target Series 6 can be supplied with
a bezel adaptor to allow installation into existing
Moisture Target Series 5 panel cut-outs.
Uses M Series Probes and
VeriDri Transmitter
The Moisture Target Series 6 uses M Series
aluminum oxide moisture sensor probe or VeriDri
moisture transmitter. M Series probes and VeriDri
transmitter are rugged and accurate true absolute
humidity sensors with calibration traceable to NIST.
Exceptional dynamic range, speed of response and
calibration stability have made the aluminum oxide
sensor the standard for performance and value in
industrial moisture measurement for more than 40
years.
Microprocessor-Based
Electronics
The microprocessor-based Moisture Target Series 6
accurately tracks fast-changing process conditions
and displays dew/frost point temperature in °F or °C
on an LCD. Dew/frost point is also available as an
analog voltage or current output, and the Moisture
Target Series 6 features built-in isolation to ensure
the integrity of signals to remote devices. The unit
also features two Form C alarm relays for high and
low dew/frost point limits. The microprocessor-based
electronics and six-button keypad combine to make
selection of analog output zero and span, alarm
setpoints fast and easy, and entry of calibration data
sample.
Series 6 Specifi cations
Electronics
Intrinsic Safety
External safety barrier for moisture input (optional)
European Compliance
Complies with EMC Directive 2004/108/EC and
2006/95/EC Low Voltage Directive (Installation
Category II, Pollution Degree II)
Input
Moisture signal from GE Sensing thin-fi lm aluminum
oxide moisture sensor on an M Series probe or VeriDri
transmitter
Analog Output
Single internal isolated recorder output for dew point,
internally optically isolated, 10-bit (0.1%) resolution
Standard Switch-Selectable Outputs
• 0 to 2 V, 10k minimum load resistance
• 0 to 20 mA, 400  maximum series resistance
• 4 to 20 mA, 400  maximum series resistance
• User-programmable within the range of the
instrument and the corresponding sensor or
transmitter
Alarm Relays
• One fail-safe fault relay
• Two standard Form C relays SPDT, rated for 3 A at
250 VAC/30 VDC
• Set to any level within the range of the instrument;
programmable from the front panel
Alarm Set Point Repeatability
±0.2°F (±0.1°C) dew point
Datalogger
32 GB capacity with MicroSD card, 2 GB card included
Display
128 x 64 matrix LCD
Display Functions
Dew point temperature in °F, °C or sensor signals for
diagnostics
Power Requirements
Universal power 100-240 VAC @ 50-60 Hz, or 24 VDC
nominal
Temperature
• Operating: –4° to 140°F (–20° to 60°C)
• Storage: –40° to 158°F (–40° to 70°C)
Warm-Up Time
Meets specifi ed accuracy within three minutes
Confi gurations
• Panel (front panel meets Type 4 and IP66)
• Board version, without enclosure
121.78
(4.79)
92.60 (3.65)
118.38
(4.66)
5.50 (.22)
57
(2.24)
104 (4.09)
45 (1.77)
93.60 (3.69)
46
(1.81)
Dimensions are in millimeters (inches).
Weight = 0.55lb (0.25kg).
PANEL CUTOUT
920-517A
© 2010 General Electric Company. All Rights Reserved. Specifi cations are subject to change without notice. GE is a registered trademark of General Electric Company. Other company or product
names mentioned in this document may be trademarks or registered trademarks of their respective companies, which are not affi liated with GE.
www.gesensinginspection.com
Series 6 Specifi cations
Moisture Measurement
Sensor Type
Thin-fi lm aluminum oxide
Moisture Probe Compatibility
Compatible with all GE M Series aluminum oxide
moisture probes and VeriDri transmitters
Dew/Frost Point Temperature
• Overall range capability: 140°F to –166°F
(60°C to –110°C)
• Standard 68°F to –112°F (20°C to –80°C) with data
to -166°F (–110°C)
• Extended 140°F to –85°F (60°C to –80°C) with data
to 166°F (–110°C)
• VeriDri ranges include:
• –110°C to 20°C
• –110°C to –50°C
• –90°C to 10°C
• –80°C to –30°C
• –80°C to 20°C
• –30°C to 20°C
• –130°F to 70°F
• –130°F to –40°F
• –40°F to 70°F
• –50°F to 50°F
• –100°F to 0°F
Calibrated Accuracy at 77°F (25°C)
• ±3.6°F (±2°C) from –85°F to 50°F (–65°C to 10°C)
• ±5.4°F (±3°C) from –112°F to –86°F (–80°C to –66°C)
Repeatability
• ±0.9°F (±0.5°C) from –85°F to 50°F (–65°C to 10°C)
dew/frost point
• ±1.8°F (±1.0°C) from –112°F to –86°F (–80°C to –66°C)
dew/frost point

產品圖片


相關產品
IC693MDL732
IC693MDL732
CNY ¥ 1
RS-E2-0285P011
RS-E2-0285P011
CNY ¥ 1
LV7000 3 0205 5-A2H0SSVA100000000
LV7000 3 0205 5-A2H0SSVA100000000
CNY ¥ 1
TPD32-EV-500/520-350-4B
TPD32-EV-500/520-350-4B
CNY ¥ 1

網站首頁  |  產品目錄  |  消息  |  聯繫我們  |  文件下載  |  網站地圖  |  手機版
  简体版     繁體版     English
Powered by DIYTrade.com
網站首頁聯繫我們網站地圖