P14DG16A6C0550A

P14DG16A6C0550A

Model No.︰P14DG16A6C0550A

Brand Name︰GE

Country of Origin︰United States

Unit Price︰CNY ¥ 1 / pc

Minimum Order︰1 pc

Inquire Now

Product Description

GE
Grid Solutions
Protection & Control
• Comprehensive current, voltage, power and
frequency protection functions
• Fast protection execution, scan rate
8 times / cycle
• Advanced protection functions including rate
of change, autoreclose, synchrocheck and
fault location
Advanced Monitoring &
Metering
• Harmonics and THD up to the 21st order
• Up to 128 samples/cycle oscillography
• Flexible elements for building customized
functions
Advanced
Communications
• Supports IEC 61850 Ed. 2, IEC 62439 (PRP/
HSR), Modbus RTU, Modbus TCP, IEC 60870-
5-103, DNP 3.0 serial and DNP 3.0 Ethernet
protocols
• IEEE 1588 (PTP), IRIG-B and SNTP time
synchronization
• Ethernet and serial protocols can operate
concurrently
Ease-of-Use
• Compact and withdrawable
• Low depth design (<155 mm)
• Universal voltage binary inputs, universal
1 A / 5 A CTs and universal power supply
• Single setting file for relay configuration
• No internal battery, for UN3091 air transit
compliance
Utility and Industrial Feeder Management Relay
The P40 Agile Enhanced feeder management relay delivers highly-adaptable protection and control
for utility and industrial feeders alike. It can be applied for primary (main) or backup protection of
underground cable and overhead line circuits. Fast overcurrent, ground fault, voltage and frequency
elements form the central core of key performance. Advanced functionality includes extensive
programmable logic and flexible configuration capabilities, plus support for industry-leading
communication protocols. P40 Agile Enhanced provides easy integration into new or existing SCADA
or DCS for real time situational-awareness.
P40 Agile Enhanced offers comprehensive power quality monitoring, plus extensive data-logging
capabilities, oscillography and events capture. Such measurement and recording features
empower users to arrive at power network decisions quickly and effectively, thereby improving
service reliability and availability levels.
Key Benefits
• Advanced protection with integrated communications
• Condition monitoring of the relay and health of substation equipment in the bay/cell
• Compact design for power distribution applications featuring universal communications, ideal for
on-switchgear installation
• High I/O density – up to 11 inputs / 11 outputs or 14 inputs / 9 outputs - in a case as small as
20TE (4 inch) width
• Extensive recording – 2048 events, 25 fault records, disturbance recording up to 128 s/c
• Embedded suite of serial and Ethernet protocols for ease of integration
• Choice of copper or fiber Ethernet interfaces
• CyberSentry™ Advanced Security including features such as AAA, Radius, RBAC, and Syslog
helps enable NERC® CIP compliance
• Designed with an IEC62443-4-1:2018 certified secure development lifecycle process
• Draw-out design for simplified testing, commissioning and maintenance
Applications
• Deploy at distribution voltage levels (as primary protection) up to transmission (as back-up)
• Solidly-grounded, through to systems with constrained fault currents, such as resistance/
impedance grounded systems.
• Networks with connected renewables requiring advanced harmonic monitoring and
accurate recording
• Fast protection pass enables load-shedding schemes
• Advanced synchronization and autoreclose schemes
• Standard, coastal, industrial and polluted environments thanks to harsh environmental coating
of PCBs as standard

Generator Protection

GE's generator protection devices provide innovative solutions for the protection, control and monitoring of generator assets. Generator protection is critical to maintaining maximum uptime in the generating facility and providing vital protection of the generating unit. From the protection and control of utility generators to ensuring safe interconnection of renewable energy sources, to synchronization and load shedding solutions using advanced automation, GE maximizes asset reliability and operational life.

 

Interactive Selector Guide

 

Large Size Generators (>40MVA)

Multilin UR protection and control relay platform

Multilin G60

The G60, a member of the UR family of protection relays, provides ultimate protection for AC generators. Provides 100% stator ground fault by low frequency injection (GPM-S module required) and field ground fault protection (GPM-F module required). It offers a large color LCD display, integrated PMU and process bus and is on the US Government GSA schedule.

 

More Info Buy Now

MiCOM P34x Agile

The P34x models, members of the MiCOM P40 Agile family of protection relays, offer cost effective protection for AC generators. They can provide 100% stator ground fault by low frequency injection (P345, GPM-S module required) and field ground fault protection (P391 module required).

 

More Info Buy Now

Small to Medium Size Generators (< 40MVA)

Multilin 889

The 889, a member of the 8 series family of protection relays, has been designed for industrial customers and small to medium utility generators. It offers a large color LCD display and Wi-Fi connectivity to configure settings and retrieve records.

 

More Info Buy Now

Ground Protection

Multilin GPM-S

The GPM-S is a Stator Ground Protection Module that provide 100% stator ground fault protection during generator start-up, running and stopped conditions. It is based on sub-harmonic injection of a 20Hz voltage to continuously monitor the integrity of the stator windings. The GPM-S can be used with either of the Multilin G60 or the MiCOM Agile P345 relays.

Multilin GPM-F

The GPM-F is a Ground Protection Module for monitoring the generator field/rotor windings. Working in combination with the Multilin G60 relay, the GPM-F provides detection of ground faults in the field winding of the generator. The device can be used for either single point or double point injection based on application requirements.

Special Applications

Multilin UR protection and control relay platform

Multilin G30

Protection of small to medium sized generators, including unit transformer protection, part of the UR family of protection relays. It offers a large color LCD display, integrated PMU and process bus.

MiCOM P341 Agile

Provides distributed generator interconnection protection and dynamic line rating protection, part of the P40 Agile family of protection relays.

Transformer Protection

GE's transformer protection devices provide innovative solutions for the protection, control and monitoring of transformer assets. Transformers have become an essential component for high voltage power transmission, ensuring long distance transmission of power is economically practical. GE's transformer protection solutions enhance transformer reliability through special techniques and methods to increase the life of transformers.

 

Extend transformer life, optimize capital expenditure and improve reliability of service by implementing a preventative asset maintenance and management tool using GE's Multilin T60, T35, 845, 745 and 345 as well as MiCOM P64x.

Learn more about this spotlight application.

 

Interactive Selector Guide

 

Power Generation & Transmission

Multilin UR protection and control relay platform

Multilin T60

The T60, a member of the UR family of protection relays, cover two and three windings transformers, with two to five windings transformer protection including interturn protection. It offers a large color LCD display and integrated PMU.

MiCOM P542/3/5 Agile

MiCOM P642/3/5 Agile

The various P64x models, part of the MiCOM P40 Agile family of protection relays, cover two and three windings transformers (including auto-transformers), providing cost effective two to five windings protection. Modular range in 4U high, 40TE (4”) 60TE (6”) and 80TE (8”) width.

 

Distribution & Industry (>5MVA)

Multilin 845

Multilin 845

The 845, a member of the 8 series family of protection relays, has been designed to provide comprehensive protection of transformers with two or three windings. Integrated transformer M&D with GE Dissolved Gas Analyzer (DGA) and advanced health report.

 

Distribution & Industry (<5MVA)

Multilin 345

Multilin 345

The 345 is ideal for protecting small and medium size, 2-winding, distribution transformers. It is available with and without draw out.

 

Special Applications

Multilin UR protection and control relay platform

Multilin T35

Cost effective transformer protection for up to six windings from the UR family of protection relays. Effective current based back-up protection for distribution. It offers a large color LCD display and process bus.

 

P50 Agile P652

P50 Agile P652

The P652 is a dedicated protection relay intended for optimized protection of two winding transformers. It is an economical choice, designed for deployment in volume, for distribution or industrial applications typically.

 

MiCOM P543/4/5/6 Agile

The P543, P544, P545 & P546 models, part of the MiCOM P40 Agile family of protection relays, constitute a cost effective range of transmission-class protection relays providing comprehensive line differential protection for 2 or 3 line ends, subcycle distance and directional earth fault protection. This range of products is ideal for HV, EHV and UHV applications on lines and cables of any length for 1 or 2 CB applications with neutral differential for high impedance faults.

 

More Info Buy Now

Multilin UR protection and control relay platform

Multilin L90

The L90, a member of the UR family of protection relays, is a transmission-class protection relay providing comprehensive line differential protection for 2 or 3 line ends, subcycle distance and directional earth fault protection. It is ideal for HV, EHV and UHV applications on lines and cables of any length for 1 or 2 CB applications. It offers a large color LCD display and integrated PMU.

 

More Info Buy Now

Line Differential with Distance - Distribution

MiCOM P54A/B/C/E Agile

MiCOM P54 A/B/C/E Agile

The P54A/B/C/E models, part of the MiCOM P40 Agile family of protection relays, provides cost effective high speed multi-ended line differential protection for overhead line and cables up to 6 ends. The P54C and P54E support a high density of binary inputs/outputs, while the P54A and P54B offer compact line differential protection in a half-rack case.

 

More Info Buy Now

Distance Protection

MiCOM P443, P446 Agile

MiCOM P443, P446 Agile

The P443 and P446 models, part of the MiCOM P40 Agile family of protection relays, constitute a range of transmission-class protection relays that provide subcycle, 6 to 9 zone, distance protection with mho/quad characteristics, delta directional comparison (incremental) protection and “Virtual current polarising” of Directional Earth/Ground Fault (DEF) and settings free PSB for 1 or 2 CBs.

 

More Info Buy Now

MiCOM P441, P442, P444 Agile

MiCOM P441, P442, P444 Agile

The P441, P442 and P444 models, part of the MiCOM P40 Agile family of protection relays, are numerical distance relays that provide flexible, fast and reliable protection of transmission and sub-transmission lines. They include full scheme 5-zone distance protection with quad characteristics, plus directional earth fault (DEF) for single breaker applications.

 

More Info Buy Now

Multilin UR protection and control relay platform

Multilin D60

The D60, a member of the UR family of protection relays, offers transmission-class protection that provides subcycle, 6 zone, distance protection with mho/quad characteristics and Directional Earth/Ground Fault (DEF) for 1 or 2 CBs. It offers a large color LCD display and integrated PMU.

 

More Info Buy Now

Railway Catenary

MiCOM P44T Agile

MiCOM P44T Agile

The P44T provides protection for railway catenary lines, supplementing a 5 zone distance main protection are a host of backup protection, thermal protection, recording, control, measurement and monitoring features. Wrong phase coupling, panto flash over, train startup and Delta I for high impedance faults protection are also included. With independently settable right and left hand side resistive reaches for each zone the P44T suits routes hosting regenerative braking trains. Protection of classic or auto transformer-fed catenaries in systems with nominal frequencies of 50 or 60 Hz.

 

More Info Buy Now

Special Applications

Multilin UR protection and control relay platform

Multilin L30

Current differential protection for sub-transmission and MV lines and cables. Part of the UR family of relays. Includes voltage based protection, metering and check synchronizing. It offers a large color LCD display, PMU and advanced Ethernet communications with IEC 61850 station and process bus.

 

More Info Buy Now

MiCOM P541, P542 Agile

MiCOM P541, P542 Agile

Current differential protection for sub-transmission and MV lines and cables. Part of the MiCOM family of relays. Available in a compact cases, 40TE (P541) or 60TE (P542).

 

More Info Buy Now

Multilin UR protection and control relay platform

Multilin L60

The L60, a member of the UR family of protection relays, provides comprehensive phase comparison line protection including 3 zone distance protection. It offers a large color LCD display.

 

More Info Buy Now

MiCOM P547 Agile

MiCOM P547 Agile

The P547, a member MiCOM P40 Agile family of protection relays, provides comprehensive phase comparison line protection including subcycle 5 zone distance protection with distance and DEF signaling schemes.

 

More Info Buy Now

Multilin UR protection and control relay platform

Multilin D30

5 zone distance protection with quad/mho characteristics for 3 pole tripping and autoreclose. Part of the UR family. Primary protection for sub-transmission lines, backup protection for MV to EHV lines. It offers a large color LCD display and integrated PMU.

 

More Info Buy Now

Multilin UR protection and control relay platform

Multilin C70

The C70 provides both the bank and system protection schemes for shunt capacitor banks. The current and voltage-based protection functions provide sensitive protection for grounded, ungrounded single, and parallel capacitor banks and banks with taps.

 

More Info Buy Now

MiCOM P841 Agile

MiCOM P841 Agile

Provides control and back-up protection in transmission and sub-transmission feeder bays, together with single or dual breaker and 1/3 pole autoreclose logic schemes and synchro check.

 

More Info Buy Now

MiCOM P842 Agile

MiCOM P842 Agile

Provides a distributed scheme for delayed auto-reclose (DAR) and auto-isolation of a mesh bus station, using high-speed real time peer-peer communication over Ethernet.

 

More Info Buy Now

Accessories

MiCOM P59x Agile

MiCOM P59x Agile

This range of standalone units enables the MiCOM Agile P54x current differential relays and MiCOM relays with InterMiCOM64 inter relay communications to be connected to remote pulse code modulation (PCM) multiplexing equipment.

Multilin B30

The B30, a member of the UR family, provides busbar protection for up to 16 feeders with 6 differential zones. Communication between bay and central units is done using Process Bus (IEC 61850-9-2LE) or standard (IEC 61869) protocols. It offers a large color LCD display. It can also be used for centralized protection for MV substations requiring busbar, breaker fail and feeder phase/neutral/ground overcurrent and under/overvoltage protection.

 

More Info Buy Now

MiCOM P741/2/3 Agile

Part of the MiCOM P40 Agile family of relays, consisting of the Agile P741 central unit and P742 and P743 peripheral units, the P74x Agile is engineered to provide a traditional distributed architecture for busbar protection with CT saturation detection and dynamic topology processing algorithms. It can accommodate up to 8 zones (plus a check zone) and up to 28 terminals.

 

More Info Buy P741 Buy P742 Buy P743

Centralized Bus Protection

Multilin UR protection and control relay platform

Multilin B90

Comprehensive and scalable bus and breaker fail protection for LV, HV and EHV busbars. The B90, a member of the UR family, supports multi-section busbars schemes of up to 24 feeders and 6 zones. It offers a large color LCD display.

 

More Info Buy Now

MiCOM P747 Agile

The P747 Agile relay, a member of the MiCOM P40 Agile family, provides complete protection up to extra high voltage busbar configurations. It can accommodate up to 4 zones (plus check zone) and protect up to 18 feeders. The P747 Is particularly useful in double busbar with double bus coupler applications due to its high number of I/Os.

 

More Info Buy Now

MiCOM P746 Agile

The P746 Agile, a member of the MiCOM P40 Agile family, provides an easy to engineer solution for smaller size MV and HV busbar configurations with up to 2 zones (plus a check zone) and up to 6 feeders (1 box) or 18 feeders (3 boxes, 1 per phase). It can also be used with process bus in 1 box applications.

 

More Info Buy Now

High Impedance Bus Differential

MiCOM P145 Agile

The MiCOM P145 numerical relay provides fast and reliable high impedance busbar differential protection. The P145 provides voltage and current based buswire supervision with 10 function keys, 18 programmable LEDs and 16I/16O for busbar protection scheme logic, control and indications.

 

More Info Buy Now

MiCOM P14NB Agile

The MiCOM P14NB numerical relay provides fast and reliable high impedance busbar differential protection in a compact case. The P14NB provides current based buswire supervision with 8I/8O and 4 programmable LEDs for busbar protection scheme logic, control and indications.

 

More Info Buy Now

MCAG

The MCAG electromechanical relays provides fast and reliable high impedance busbar differential protection. Settings are in amps.

 

More Info Buy Now

MFAC

The MFAC electromechanical relays provides fast and reliable high impedance busbar differential protection. Settings are in volts.

 

More Info  Buy Now

MVTP

The MVTP provides continuous voltage supervision of the buswires in high impedance busbar protection schemes to detect open-circuited buswires as well as open-circuited main current transformers.

 

More Info Buy Now

HID

The HID module provides stabilizing resistors together with voltage limiters (MOVs) to achieve high impedance differential protection with MiCOM P14x numerical relays. External Metrosils and stabilizing resistors used with the MCAG/MFAC relays for high impedance differential protection can also be used with the P14x relays.

 

More Info Buy Now

Accessories

KITZ 274

The KITZ 274 provides conversion between K-BUS ports to adapt P74x relays to IEC 60870-5-103 protocol